Explore UAB
  • Picture3
    Flow Cytometry and Single Cell Core Facility
  • Flow Cytometry and Single Cell Core Facility
  • Flow Cytometry and Single Cell Core Facility
  • Flow Cytometry and Single Cell Core Facility
  • Flow Cytometry and Single Cell Core Facility
  • Flow Cytometry and Single Cell Core Facility
  • Flow Cytometry and Single Cell Core Facility

  • BD FACSymphony S6 at Shelby 231
         
    • Lasers: Five
    • UV (355 nm)
    • Violet (405 nm)
    • Blue (488 nm)
    • Yellow Green (561 nm)
    • Red (637 nm)

    • Parameters: 30 fluorescence and 2 scatter.
    • Nozzle sizes: 70, 85, 100, and 130 microns.

    • Additional features:
    • Six-way sorting into 1.5 ml and 5 ml tubes.
    • Plate sorting into 96 and 384 well plates.
    • Index sorting.
    • Biosafety: Baker BioPROTECT cabinets

    Configuration    Reserve

     
  • BD FACSAria SORP at Shelby 231
         
    • Lasers: Four
    • Violet (405 nm)
    • Blue (488 nm)
    • Yellow Green (561 nm)
    • Red (640 nm)

    • Parameters: 16 fluorescence and 2 scatter.
    • Nozzle sizes: 70, 85, and 100 microns.

    • Additional features:
    • Four-way sorting into 1.5 ml and 5 ml tubes.
    • Two-way sorting into 15 ml tubes.
    • Plate sorting into 96 and 384 well plates.
    • Index sorting.
    • Biosafety: Baker BioPROTECT cabinets

    Configuration    Reserve

     
  • BD FACSAria II at Shelby 231
         
    • Lasers: Three
    • Violet (405 nm)
    • Blue (488 nm)
    • Red (640 nm)

    • Parameters: 9 fluorescence and 2 scatter.
    • Nozzle sizes: 70, 85, and 100 microns.

    • Additional features:
    • Four-way sorting into 1.5 ml and 5 ml tubes.
    • Two-way sorting into 15 ml tubes.
    • Plate sorting into 96 and 384 well plates.
    • Biosafety: Baker BioPROTECT cabinets

    Configuration    Reserve

     
  • BD FACSMelody at Shelby 231
         
    • Lasers: Three
    • Violet (405 nm)
    • Blue (488 nm)
    • Red (640 nm)

    • Parameters: 9 fluorescence and 2 scatter.
    • Nozzle sizes: 100 microns.

    • Additional features:
    • Two-way sorting into 1.5 ml and 5 ml tubes.
    • Plate sorting into 96 and 384 well plates.
    • Index sorting.
    • Biosafety: Baker SterilGARD

    Configuration    Reserve

     
  • BD FACSAria IIIu at Bevill 569
         
    • Lasers: Four
    • Violet (405 nm)
    • Blue (488 nm)
    • Yellow Green (561nm)
    • Red (633 nm)

    • Parameters: 15 fluorescence and 2 scatter.
    • Nozzle sizes: 70, 85, and 100 microns.

    • Additional features:
    • Four-way sorting into 1.5 ml and 5 ml tubes.
    • Two-way sorting into 15 ml tubes.
    • Plate sorting into 96 and 384 well plates.
    • Index sorting.
     

    Configuration    Reserve

     
  • BD FACSMelody at Bevill 569
         
    • Lasers: Three
    • Violet (405 nm)
    • Blue (488 nm)
    • Red (640 nm)

    • Parameters: 9 fluorescence and 2 scatter.
    • Nozzle sizes: 100 microns.

    • Additional features:
    • Two-way sorting into 1.5 ml and 5 ml tubes.
    • Plate sorting into 96 and 384 well plates.
    • Index sorting.
    • Biosafety: Baker SterilGARD

    Configuration    Reserve